TLC5000 12 Channel Holter ECG Monitoring System

Recorder Features
* With advanced design and technology, the recorder can work stably, dependable and durable.
* Be provided with the capability of anti-jamming and shock-pro.
* Small volume with OLED screen. The resolution is 160*128.
* Be provided with functions of waveform preview, record review and event marking.
* Accurate record of the start time of the data sampled owing to the real time clock of itself.
* Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
* The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
* The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
* Record waveform details inextenso by the design of high precision and sampling frequency.
* Record the state of pacemaker exactly by higher sampling frequency.
* International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG.

The features of software
* Quick and accurate analysis system.
* With 12 leads synchro analysis , QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
* Optional main channel.
* Agile and exact "Atrial Fibrillation" analysis.
* The function of pacing analysis could analyse all pacemakers.
* Many pacine modules have been added.
* Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
* The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
* Print report expediently.
* Perfect function of case management.
* With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
* "Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose.
* "HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
15."T Wave alternation" analysis is a important index on judging and preventing Arrhythmia .
* The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.

Standard

Number of channels: 12 channels;
Sampling rate:10000Hz;
Sampling accuracy:12bit;
Recording time : 24 h;
Power: 2 batteries in size 5;
Interface: USB2.0;
Scale voltage:1mV±5%;
Standard Sensitivity:10mm/mV±5%;
Noise level:≤30μV;
CMRR:≥60dB;
Feathers of low frequency : Time constant>3.2s;
Scan speed:25mm/s±5%;
Enduring polarization voltage:±300mV;
Least measure signal : 50 µV p-p;
Product safety type : Type B (Internally powered);
Size:111mm(L)*60mm(W)*25mm(H);